Painting cabin GVS
Painting cabin designed for the dry filtering of paint fumes.
The series GVS painting cabins carry out the dry filtering of paint fumes. The suction vent is positioned on the roof of the cabin, while the suction unit can be positioned on the roof or on the ground.
The cabins are complete with electric panel, lights and differential pressure switch for signalling the degree of blockage of the filters.
Filtration stage 1: Accordion filter
Efficiency at 0,75 m/sec: 91-98% (ASHRAE 2.76)
Dust accumulation: 3-18 kg/m2
Loss of charge: 130-250 Pa
Filtration stage 2: Fibreglass cells
Stoppage: G3 (EN779G3)
Dust accumulation: 5-6 kg/m2
Loss of charge: 40-140 Pa
Applicazioni
Solvents VaporsContact us now
GRT DARMA technicians and engineers are at your disposalto provide you with further information or the quote you need.
+39 011 701222